{"id":7696,"date":"2026-02-26T10:58:37","date_gmt":"2026-02-26T10:58:37","guid":{"rendered":"https:\/\/teceudemo.com\/accelerated-aging-test\/"},"modified":"2026-04-10T12:58:50","modified_gmt":"2026-04-10T12:58:50","slug":"accelerated-aging-test","status":"publish","type":"page","link":"https:\/\/www.tec-eurolab.com\/en\/accelerated-aging-test\/","title":{"rendered":"Accelerated aging test"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"7696\" class=\"elementor elementor-7696 elementor-4633\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6cf8f0 e-flex e-con-boxed e-con e-parent\" data-id=\"a6cf8f0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4692de6 elementor-widget elementor-widget-heading\" data-id=\"4692de6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Accelerated aging test<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1fb0f9f elementor-align-center elementor-widget elementor-widget-breadcrumbs\" data-id=\"1fb0f9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"breadcrumbs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<nav aria-label=\"breadcrumbs\" class=\"rank-math-breadcrumb\"><p><span class=\"last\">Home<\/span><\/p><\/nav>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-69fe856 e-flex e-con-boxed e-con e-parent\" data-id=\"69fe856\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6227690 e-con-full e-flex e-con e-child\" data-id=\"6227690\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-83a1ae4 elementor-widget elementor-widget-image\" data-id=\"83a1ae4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/test-invecchiamento-accelerato-1024x576.webp\" class=\"attachment-large size-large wp-image-7682\" alt=\"Accelerated aging test\" srcset=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/test-invecchiamento-accelerato-1024x576.webp 1024w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/test-invecchiamento-accelerato-300x169.webp 300w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/test-invecchiamento-accelerato-768x432.webp 768w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/test-invecchiamento-accelerato-1536x864.webp 1536w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/test-invecchiamento-accelerato.webp 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d2f4436 e-flex e-con-boxed e-con e-parent\" data-id=\"d2f4436\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-53f4066 e-con-full e-flex e-con e-child\" data-id=\"53f4066\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-96303c2 e-con-full e-flex e-con e-child\" data-id=\"96303c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c4a247 elementor-widget elementor-widget-text-editor\" data-id=\"1c4a247\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Accelerated aging tests<\/strong> are <a href=\"https:\/\/www.tec-eurolab.com\/en\/environmental-and-functional-tests\/\">environmental tests<\/a> designed to simulate, in a reduced amount of time, the effects of prolonged exposure to environmental and operational factors on materials and products. These tests are critical for evaluating the <strong>durability, reliability, and strength<\/strong> of components intended for industries such as aerospace, automotive, electronics, and biomedical, where long-term safety and performance are essential requirements. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c5e6a5e e-con-full e-flex e-con e-child\" data-id=\"c5e6a5e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6e4893 elementor-widget elementor-widget-text-editor\" data-id=\"b6e4893\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Aging can be induced through several methods, including exposure to temperature and humidity cycles, UV radiation, salt spray, or repeated mechanical stresses. These tests allow early identification of possible degradation, prevention of failure, and optimization of materials and production processes. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4200bf5 elementor-tablet-align-center elementor-widget elementor-widget-button\" data-id=\"4200bf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">REQUEST A TEST<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a527d8f e-flex e-con-boxed e-con e-parent\" data-id=\"a527d8f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-a247c13 e-con-full e-flex e-con e-child\" data-id=\"a247c13\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-27621c4 e-con-full e-flex e-con e-child\" data-id=\"27621c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8224380 elementor-widget elementor-widget-heading\" data-id=\"8224380\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Accelerated Aging tests?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f965c69 elementor-widget elementor-widget-text-editor\" data-id=\"f965c69\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Accelerated aging tests <strong>aim to predict the behavior of materials, components and products over time<\/strong>, identifying any critical issues related to degradation. These tests allow the effects of wear, corrosion, oxidation and other deterioration phenomena to be simulated in the laboratory, offering reliable data in a much shorter time frame than natural aging. <strong>With these tests, companies can optimize materials, improve manufacturing processes<\/strong>, and ensure consistent performance throughout the product&#8217;s useful life. <\/p><p><strong>Accelerated aging tests follow protocols defined by international standards<\/strong>, established by bodies such as ASTM (American Society for Testing and Materials), ISO (International Organization for Standardization) and IEC (International Electrotechnical Commission). Among the most relevant standards <strong>ASTM G154<\/strong> and <strong>ASTM G155<\/strong> regulate exposure to UV radiation and weathering, ISO 11341 is the standard for aging tests on coatings, and IEC 60068 defines test methods for electronic equipment subject to severe environmental conditions. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f7ddcb e-flex e-con-boxed e-con e-parent\" data-id=\"9f7ddcb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6a1f38e e-con-full e-flex e-con e-child\" data-id=\"6a1f38e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9355ab6 e-con-full e-flex e-con e-child\" data-id=\"9355ab6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1036e84 elementor-widget elementor-widget-heading\" data-id=\"1036e84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Types of Accelerated Aging Tests<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c260a0 elementor-widget elementor-widget-text-editor\" data-id=\"7c260a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Accelerated aging tests are based on several techniques that simulate extreme environmental conditions to which materials and products may be exposed over time. These tests allow degradation to be simulated in a shorter time frame than natural aging, accelerating deterioration processes and providing useful results for durability assessment. <br>Some of the most common techniques include:<\/p><ul><li><strong>Exposure to UV radiation and artificial light<\/strong>: used to assess the photodegradation resistance of polymers, paints and coatings.<\/li><li><strong>Temperature and humidity cycles<\/strong>: tests that subject materials to extreme temperature changes and controlled levels of humidity to verify resistance to thermal stress and expansion\/contraction phenomena.<\/li><li><a href=\"https:\/\/www.tec-eurolab.com\/en\/salt-spray\/\"><strong>Salt spray test<\/strong><\/a>: test aimed at evaluating the corrosion resistance of metallic materials and protective coatings<\/li><li><strong>Mechanical stresses and fatigue cycles<\/strong>: tests that simulate dynamic and repeated stresses on a material or component to verify its resistance to wear and mechanical stress over time.<\/li><\/ul><p>In addition to these methodologies, there are <strong>combined tests that integrate multiple aging factors<\/strong> (such as temperature, humidity, and UV radiation) to more faithfully reproduce the actual conditions of product use.<\/p><p>The choice of the most suitable technique depends on the area of application and the specific performance requirements for the material or component being tested.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a03eea5 e-con-full e-flex e-con e-child\" data-id=\"a03eea5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9f92b0 elementor-widget elementor-widget-heading\" data-id=\"a9f92b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Simulated environmental conditions in the tests<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62c0bf0 elementor-widget elementor-widget-text-editor\" data-id=\"62c0bf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In accelerated aging tests, accurate control of environmental variables is essential to accurately simulate the conditions to which a material or component will be exposed over time. The <strong>main variables controlled<\/strong> include: <\/p><ul><li><strong>Temperature<\/strong>: Thermal variations can cause expansion, contraction and degradation phenomena in materials. Tests can involve extreme and rapid heating and cooling cycles (thermal shock tests), reproducing real or simulated operating conditions. <\/li><li><strong>Humidity<\/strong>: Exposure to controlled levels of relative humidity makes it possible to study phenomena such as water absorption, polymer degradation and condensation formation, aspects critical to the reliability of electronic devices and organic materials.<\/li><li><strong>UV radiation and artificial light<\/strong>: Solar radiation is a major cause of aging of plastics, paints and coatings. Accelerated light exposure tests simulate the effect of photodegradation and loss of mechanical and aesthetic properties over time. <\/li><li><strong>Salt spray<\/strong>: Essential for testing the corrosion resistance of metals and protective coatings.<\/li><li><strong>Mechanical stresses<\/strong>: Vibration, cyclic loads, and mechanical fatigue can accelerate the aging of structural components and assemblies. These tests help identify possible weaknesses in the design and materials used. <\/li><\/ul><p>By fine-tuning these variables, <strong>accelerated aging tests make it possible to gather reliable data on the durability of products<\/strong> and predict their long-term behavior, helping to improve their quality and durability over time.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ed6b3e elementor-tablet-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"7ed6b3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">REQUEST A TEST<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5337bd5 e-con-full e-flex e-con e-child\" data-id=\"5337bd5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05a1a0d elementor-widget elementor-widget-heading\" data-id=\"05a1a0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Accelerated aging methods<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34126b0 elementor-widget elementor-widget-text-editor\" data-id=\"34126b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>At TEC Eurolab, accelerated aging tests are performed using advanced methodologies and state-of-the-art instrumentation to realistically simulate the extreme environmental conditions to which materials and components may be exposed over time. Using a customized approach, we define specific test protocols based on the application area and customer needs. In our materials analysis laboratory, we perform a wide range of accelerated aging environmental tests to verify the durability and strength of material subjected to extreme conditions. The Test Engineering department, on the other hand, specializes in performing custom tests on components of non-standard geometries, going to meet requirements of a specific nature and outside international standards.   <\/p><p>At TEC Eurolab we perform the following accelerated aging tests:<\/p><ul><li><a href=\"https:\/\/www.tec-eurolab.com\/en\/corrosion-and-environmental-conditioning\/\">Corrosion<\/a> and <a href=\"https:\/\/www.tec-eurolab.com\/en\/salt-spray\/\">salt spray testing<\/a>: we simulate corrosive environments with high humidity and the presence of salt spray to test the corrosion resistance of metals and protective treatments<\/li><li><a href=\"https:\/\/www.tec-eurolab.com\/en\/fatigue-testing-dynamic-mechanical-testing\/\">Fatigue testing<\/a>: we apply cyclic loads and vibration to simulate the actual operating conditions of materials and structural components, identifying any critical issues related to wear and mechanical failure.<\/li><li><a href=\"https:\/\/www.tec-eurolab.com\/climatic-chamber-test\/\">Climate chamber and thermal shock testing<\/a>: we simulate controlled temperature and humidity variations by running thermal stress cycles to reproduce real-world conditions of use, evaluating the behavior of polymeric, electronic, and metallic materials.<\/li><li><strong>Accelerated aging test with UV radiation<\/strong>: we simulate prolonged exposure to ultraviolet radiation to evaluate the effect on the integrity and performance of materials.<\/li><\/ul><p>By fine-tuning these variables, <strong>accelerated aging tests make it possible to gather reliable data on the durability of products<\/strong> and predict their long-term behavior, helping to improve their quality and durability over time.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a792a72 e-flex e-con-boxed e-con e-parent\" data-id=\"a792a72\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-35d5a9d e-con-full e-flex e-con e-child\" data-id=\"35d5a9d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-5e206f7 e-con-full e-flex e-con e-child\" data-id=\"5e206f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a019f09 elementor-widget elementor-widget-heading\" data-id=\"a019f09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Accelerated aging test planning in TEC Eurolab: steps and strategies\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d96a22 elementor-widget elementor-widget-text-editor\" data-id=\"3d96a22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Planning an accelerated aging test is a multifaceted process<\/strong> that requires careful definition of objectives, thorough preparation, and detailed analysis of results to ensure reliable and meaningful data. An important variable is the definition of the accelerated aging method to be adopted. This depends on the testing needs of the customer, the product to be tested (whether component or material), and the environmental conditions to be simulated. At TEC Eurolab, each stage of the test is handled with a <strong>rigorous, customized approach<\/strong> to meet the specific needs of the customer and ensure maximum accuracy in the results.   <\/p><p>The <strong>main steps in test planning<\/strong> include:<\/p><ol><li><strong>Definition of objectives and choice of methodology<\/strong>: Before starting the test, it is essential to establish the objectives of the test, i.e., which characteristics of the material or component are to be evaluated (mechanical strength, thermal behavior, corrosion or UV resistance, etc.). Based on these requirements, we select the most suitable methodology, taking into account the environmental conditions to be simulated and the relevant standards. <\/li><li><strong>Test set-up<\/strong>: materials or components to be tested are selected and prepared according to technical specifications and test requirements. This may include preliminary treatments, initial measurements, and the set-up of sensors to monitor parameters during the test. The set-up phase is crucial to ensure reproducibility and reliability of the data collected.  <\/li><li><strong>Test execution<\/strong>: The test is conducted according to the established method, monitoring key variables such as temperature, humidity, UV exposure, salt spray or mechanical stress in real time. During this phase, continuous data are collected to identify any changes in the properties of the tested material or component. <\/li><li><strong>Analysis, data interpretation, and report preparation<\/strong>: Once the test is completed, the collected data are processed to identify degradation phenomena, structural or functional changes, and possible critical issues. TEC Eurolab provides a detailed test report to help customers interpret the results and make informed decisions about product performance and reliability. <\/li><\/ol><p>Through this structured methodology and the use of advanced tools, TEC Eurolab is able to provide reliable and customized testing, helping companies validate the quality of their products and improve their durability over time.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5d77358 e-flex e-con-boxed e-con e-parent\" data-id=\"5d77358\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-a4c8e30 e-con-full e-flex e-con e-child\" data-id=\"a4c8e30\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7e17984 elementor-widget elementor-widget-image\" data-id=\"7e17984\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"812\" src=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/prove-di-invecchiamento-accelerato-1009x1024.webp\" class=\"attachment-large size-large wp-image-7683\" alt=\"accelerated aging test\" srcset=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/prove-di-invecchiamento-accelerato-1009x1024.webp 1009w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/prove-di-invecchiamento-accelerato-296x300.webp 296w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/prove-di-invecchiamento-accelerato-768x779.webp 768w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/prove-di-invecchiamento-accelerato.webp 1074w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2165ef e-con-full e-flex e-con e-child\" data-id=\"b2165ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f6e941a elementor-widget elementor-widget-heading\" data-id=\"f6e941a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Looking for an experienced partner for reliable and certified accelerated aging tests?<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d07f783 elementor-tablet-align-left elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"d07f783\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">CONTACT US<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f3a99d e-flex e-con-boxed e-con e-parent\" data-id=\"4f3a99d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dbf2c56 e-con-full e-flex e-con e-child\" data-id=\"dbf2c56\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-41bd733 e-con-full e-flex e-con e-child\" data-id=\"41bd733\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbc3532 elementor-widget elementor-widget-heading\" data-id=\"dbc3532\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sectors and Industries of Application\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b213d0 elementor-widget elementor-widget-text-editor\" data-id=\"1b213d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\tAccelerated aging tests are widely used in various industries where durability, safety and reliability of materials and components are essential requirements.\n\nAmong the application areas of accelerated aging tests:\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1d07e64 e-con-full e-flex e-con e-child\" data-id=\"1d07e64\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9c3fc elementor-widget elementor-widget-text-editor\" data-id=\"1f9c3fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Aerospace<\/strong>: Materials and components used in extreme environments, such as aircraft and satellites, must withstand extreme temperatures, UV radiation and intense mechanical stress. Accelerated aging tests help verify structural stability and maintenance of performance over time <\/li><li><strong>Automotive industry<\/strong>: Prolonged exposure to temperature changes, humidity and corrosives is critical for vehicle components. These tests are critical to ensure the durability of plastics, coatings, seals and electronic systems, improving vehicle reliability and safety. <\/li><li><strong>Electronics and Semiconductors<\/strong>: Electronic devices must maintain their functionality even after years of use. Aging tests allow testing the stability of printed circuit boards, connectors and batteries under extreme environmental conditions. <\/li><li><strong>Plastic materials and coatings<\/strong>: Paints, polymers and protective coatings are tested for weathering and UV resistance, ensuring the durability of surfaces exposed to critical environmental conditions.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28dff86 elementor-widget elementor-widget-menu-anchor\" data-id=\"28dff86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"form\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8a3eaec e-flex e-con-boxed e-con e-parent\" data-id=\"8a3eaec\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6867cfc e-con-full e-flex e-con e-child\" data-id=\"6867cfc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6a5dad1 e-con-full e-flex e-con e-child\" data-id=\"6a5dad1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-44acec8 elementor-widget elementor-widget-heading\" data-id=\"44acec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Do you want to discover the potential of industrial tomography applied to your product?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3670843 elementor-widget elementor-widget-text-editor\" data-id=\"3670843\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\tAsk for information \n\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-df5caa1 e-con-full e-flex e-con e-child\" data-id=\"df5caa1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-db0cec1 elementor-button-align-stretch elementor-widget elementor-widget-global elementor-global-9033 elementor-global-8569 elementor-widget-form\" data-id=\"db0cec1\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;button_width&quot;:&quot;100&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"Testing module\" aria-label=\"Testing module\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"7696\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"db0cec1\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-above\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-50 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tCompany\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-lg  elementor-field-textual\" placeholder=\"Company\" required=\"required\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-50 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tEmail\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-lg  elementor-field-textual\" placeholder=\"Email\" required=\"required\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-nome elementor-col-50\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-nome\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tName\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[nome]\" id=\"form-field-nome\" class=\"elementor-field elementor-size-lg  elementor-field-textual\" placeholder=\"Name\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tSubject of the request\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-lg\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Subject of the request\" required=\"required\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-upload elementor-field-group elementor-column elementor-field-group-upload_1 elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-upload_1\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tUPLOAD ATTACHMENTS\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t<input type=\"file\" name=\"form_fields[upload_1]\" id=\"form-field-upload_1\" class=\"elementor-field elementor-size-lg  elementor-upload-field\" data-maxsize=\"15\" data-maxsize-message=\"This file exceeds the maximum allowed size.\">\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-html elementor-field-group elementor-column elementor-field-group-field_e3b5c45 elementor-col-100\">\n\t\t\t\t\t(max size 10 Mb - allowed formats pdf, doc)\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-acceptance elementor-field-group elementor-column elementor-field-group-privacy elementor-col-100 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t<div class=\"elementor-field-subgroup\">\n\t\t\t<span class=\"elementor-field-option\">\n\t\t\t\t<input type=\"checkbox\" name=\"form_fields[privacy]\" id=\"form-field-privacy\" class=\"elementor-field elementor-size-lg  elementor-acceptance-field\" required=\"required\">\n\t\t\t\t<label for=\"form-field-privacy\">I authorize the processing of personal data to follow up my request as stated in the <a href=\"https:\/\/www.privacylab.it\/informativa.php?04432308039\" target=\"_blank\" rel=\"noopener\">privacy policy<\/a><span style=\"color:#ff0000;\"> *<\/span><\/label>\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-acceptance elementor-field-group elementor-column elementor-field-group-privacy_2 elementor-col-100\">\n\t\t\t\t\t\t\t<div class=\"elementor-field-subgroup\">\n\t\t\t<span class=\"elementor-field-option\">\n\t\t\t\t<input type=\"checkbox\" name=\"form_fields[privacy_2]\" id=\"form-field-privacy_2\" class=\"elementor-field elementor-size-lg  elementor-acceptance-field\">\n\t\t\t\t<label for=\"form-field-privacy_2\">I provide consent to the processing of personal data for marketing purposes as outlined in the <a href=\"https:\/\/www.privacylab.it\/informativa.php?04432449333\" target=\"_blank\" rel=\"noopener\">privacy policy<\/a> and declare that I am at least 14 years of age.<\/label>\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-100 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-lg\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Send<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Home Accelerated aging tests are environmental tests designed to simulate, in a reduced amount of time, the effects of prolonged exposure to environmental and operational factors on materials and products. These tests are critical for evaluating the durability, reliability, and strength of components intended for industries such as aerospace, automotive, electronics, and biomedical, where long-term [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-7696","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages\/7696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/comments?post=7696"}],"version-history":[{"count":3,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages\/7696\/revisions"}],"predecessor-version":[{"id":12936,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages\/7696\/revisions\/12936"}],"wp:attachment":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/media?parent=7696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}