{"id":13586,"date":"2026-04-29T09:53:45","date_gmt":"2026-04-29T07:53:45","guid":{"rendered":"https:\/\/www.tec-eurolab.com\/industrial-tomography\/"},"modified":"2026-06-10T11:25:57","modified_gmt":"2026-06-10T09:25:57","slug":"industrial-tomography","status":"publish","type":"page","link":"https:\/\/www.tec-eurolab.com\/en\/industrial-tomography\/","title":{"rendered":"Industrial Tomography"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"13586\" class=\"elementor elementor-13586 elementor-13563\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6cf8f0 e-flex e-con-boxed e-con e-parent\" data-id=\"a6cf8f0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4692de6 elementor-widget elementor-widget-heading\" data-id=\"4692de6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Industrial Tomography<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1fb0f9f elementor-align-center elementor-widget elementor-widget-breadcrumbs\" data-id=\"1fb0f9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"breadcrumbs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<nav aria-label=\"breadcrumbs\" class=\"rank-math-breadcrumb\"><p><span class=\"last\">Home<\/span><\/p><\/nav>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-69fe856 e-flex e-con-boxed e-con e-parent\" data-id=\"69fe856\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6227690 e-con-full e-flex e-con e-child\" data-id=\"6227690\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-83a1ae4 elementor-widget elementor-widget-image\" data-id=\"83a1ae4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-industriale-1024x576.webp\" class=\"attachment-large size-large wp-image-7934\" alt=\"\" srcset=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-industriale-1024x576.webp 1024w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-industriale-300x169.webp 300w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-industriale-768x432.webp 768w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-industriale-1536x864.webp 1536w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-industriale.webp 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d2f4436 e-flex e-con-boxed e-con e-parent\" data-id=\"d2f4436\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-53f4066 e-con-full e-flex e-con e-child\" data-id=\"53f4066\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-96303c2 e-con-full e-flex e-con e-child\" data-id=\"96303c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c4a247 elementor-widget elementor-widget-text-editor\" data-id=\"1c4a247\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Industrial tomography<\/strong> is <a href=\"https:\/\/www.tec-eurolab.com\/en\/non-destructive-testing\/\">non-destructive testing<\/a>, an advanced technology that <strong>allows detailed three-dimensional images of an object to be obtained<\/strong> <strong>using X-rays <\/strong>. <\/p><p>This technique is <strong>critical for the analysis and verification of components and their material<\/strong> (material tomography), allowing detection of defects, inclusions, and porosity that would otherwise be invisible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c5e6a5e e-con-full e-flex e-con e-child\" data-id=\"c5e6a5e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6e4893 elementor-widget elementor-widget-text-editor\" data-id=\"b6e4893\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Industrial tomography, or industrial computed tomography, is widely used in various industries, such as automotive (automotive tomography) and aerospace, to ensure the quality and reliability of components.<\/p><p>At our industrial tomography center, we can perform tomographic analysis and obtain a tomographic scan that allows us to perform dimensional analysis, defect analysis, and reverse engineering of the analyzed component.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4200bf5 elementor-tablet-align-center elementor-widget elementor-widget-button\" data-id=\"4200bf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">REQUEST TOMOGRAPHIC TEST<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a527d8f e-flex e-con-boxed e-con e-parent\" data-id=\"a527d8f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-a247c13 e-con-full e-flex e-con e-child\" data-id=\"a247c13\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-27621c4 e-con-full e-flex e-con e-child\" data-id=\"27621c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8224380 elementor-widget elementor-widget-heading\" data-id=\"8224380\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Industrial computed tomography: the laboratory\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f965c69 elementor-widget elementor-widget-text-editor\" data-id=\"f965c69\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"et_pb_row et_pb_row_4\"><div class=\"et_pb_column et_pb_column_4_4 et_pb_column_6 et_pb_css_mix_blend_mode_passthrough et-last-child\"><div class=\"et_pb_module et_pb_text et_pb_text_3 et_pb_text_align_left et_pb_bg_layout_light\"><div class=\"et_pb_text_inner\"><p>TEC Eurolab&#8217;s industrial computed tomography center supports companies in the acquisition and interpretation of X-ray scans of industrial components, enabling in-depth product analysis and evaluation of possible defects.<\/p><p>Using tomographic scans, we can perform<strong> several types of analysis<\/strong>:<strong>defect analysis<\/strong>, which allows us to detect defects, inclusions and porosity in materials;<strong>dimensional analysis<\/strong>, which verifies the dimensions and conformity of components to the technical drawing; and <strong>reverse engineering<\/strong>, which allows us to derive the CAD model from the physical component.<\/p><p><strong>Industrial computed tomography is also optimal for <a href=\"https:\/\/www.tec-eurolab.com\/en\/fai-first-article-inspection\/\">FAI<\/a><\/strong><a href=\"https:\/\/www.tec-eurolab.com\/en\/fai-first-article-inspection\/\"> (First Article Inspection)<\/a>, ensuring that the first production items meet all the specifications required at the design stage.<br\/>In addition, it is often used for whole-batch production inspections, ensuring consistent quality.<\/p><p>Our experience in industrial tomography, combined with the expertise of our technical staff in choosing the most suitable instrumentation, setting parameters, and interpreting tomographic scans, enables us to <strong>support the customer at all stages of the process, from prototype analysis to analysis on the finished component.<\/strong><\/p><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5997dad elementor-tablet-align-center elementor-widget elementor-widget-button\" data-id=\"5997dad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">CONTACT THE LABORATORY<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5d77358 e-flex e-con-boxed e-con e-parent\" data-id=\"5d77358\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-a4c8e30 e-con-full e-flex e-con e-child\" data-id=\"a4c8e30\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7e17984 elementor-widget elementor-widget-image\" data-id=\"7e17984\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"812\" src=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-1-1009x1024.webp\" class=\"attachment-large size-large wp-image-7119\" alt=\"\" srcset=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-1-1009x1024.webp 1009w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-1-296x300.webp 296w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-1-768x779.webp 768w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/tomografia-1.webp 1074w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2165ef e-con-full e-flex e-con e-child\" data-id=\"b2165ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f6e941a elementor-widget elementor-widget-heading\" data-id=\"f6e941a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Discover the potential of CT Scan<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d07f783 elementor-tablet-align-left elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"d07f783\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">CONTACT THE LABORATORY<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a792a72 e-flex e-con-boxed e-con e-parent\" data-id=\"a792a72\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-35d5a9d e-con-full e-flex e-con e-child\" data-id=\"35d5a9d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-5e206f7 e-con-full e-flex e-con e-child\" data-id=\"5e206f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a019f09 elementor-widget elementor-widget-heading\" data-id=\"a019f09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The advantages of industrial tomography ndt\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d96a22 elementor-widget elementor-widget-text-editor\" data-id=\"3d96a22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Industrial tomography<\/strong> has become a nondestructive technology now indispensable in the <strong>quality control of major industries.<\/strong><\/p><p>Using industrial computed tomography, <strong>detailed three-dimensional images of complex components<\/strong> can be obtained, allowing in-depth analysis without damaging the material and the component being scanned. An in-depth investigation of the component using tomographic scanning allows the identification of possible defects, enabling companies to envisage corrective actions before proceeding with the final production or marketing of the component. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c805f84 e-con-full e-flex e-con e-child\" data-id=\"c805f84\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3eb3fb9 elementor-widget elementor-widget-text-editor\" data-id=\"3eb3fb9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Performing tomographic analysis means bringing together <strong>dimensional inspection and complete defect control<\/strong> in a single nondestructive analysis, enabling early detection of any critical issues, improving engineering confidence on the product and drastically reducing time to market.<br\/><br\/>What are the <strong>benefits for the customer?<br\/><\/strong><br\/> &#8211; <strong>Strengthening control<\/strong> over the quality of their products.<br\/>&#8211; <strong>Supporting R&#038;D departments<\/strong> during prototyping of new components.<br\/>&#8211; Checking <strong>in production<\/strong> for compliance.<br\/>&#8211; <strong>Reducing the time<\/strong> to search for causes of defects in a product.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f7ddcb e-flex e-con-boxed e-con e-parent\" data-id=\"9f7ddcb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6a1f38e e-con-full e-flex e-con e-child\" data-id=\"6a1f38e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9355ab6 e-con-full e-flex e-con e-child\" data-id=\"9355ab6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1036e84 elementor-widget elementor-widget-heading\" data-id=\"1036e84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What analysis can you do with industrial tomography and what results can you get?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c260a0 elementor-widget elementor-widget-text-editor\" data-id=\"7c260a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In our tomography center, we offer a wide range of advanced services to meet the needs of different industries.<\/p><p>Below, the <strong>main types of analysis that can be performed by tomographic scanning<\/strong> will be explained.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a03eea5 e-con-full e-flex e-con e-child\" data-id=\"a03eea5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9f92b0 elementor-widget elementor-widget-heading\" data-id=\"a9f92b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Defect analysis<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62c0bf0 elementor-widget elementor-widget-text-editor\" data-id=\"62c0bf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Following tomographic scanning of a component and reconstruction of the resulting tomographic volume, defect analysis allows <strong>the state of the component, without damaging it<\/strong>, to be <strong>defined<\/strong> in terms of:<\/p><p>Evaluation of internal discontinuities according to acceptability specifications and issuance of Accept\/Reject judgment<br\/>Classification of discontinuities in terms of extent in the 3 dimensions, type and position with respect to the CAD of the component<br\/>Definition of the total volume occupied by the discontinuities with respect to the total volume of the component with the application of specific &#8220;Porosity&#8221; calculation modules<br\/>Import of the mathematical models of the component and verification of the removability of discontinuities detected during the processing phase for In-Process and Cost Saving controls<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5337bd5 e-con-full e-flex e-con e-child\" data-id=\"5337bd5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05a1a0d elementor-widget elementor-widget-heading\" data-id=\"05a1a0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Dimensional analysis\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34126b0 elementor-widget elementor-widget-text-editor\" data-id=\"34126b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Industrial computed tomography, in addition to applications in NDT (Non Destructive Testing), has high potential in the field of dimensional analysis.<\/p><p>Unlike standard measurement technologies, in fact, the X-ray traversal of all parts of the inspected sample allows <strong>reconstruction of the entire volume of the component<\/strong> (both external and internal surfaces). In this way, during the data analysis phase it is possible to perform measurements even on all those portions of the material normally precluded by a traditional inspection, unless the sample is sectioned making it unusable. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b909ae e-con-full e-flex e-con e-child\" data-id=\"1b909ae\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9c61fc elementor-widget elementor-widget-heading\" data-id=\"a9c61fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">New product validation\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-496d5f8 elementor-widget elementor-widget-text-editor\" data-id=\"496d5f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The purpose of first-product validation is to give objective evidence that drawings, dimensions and all design specifications are verified and classified with the<strong>intent of bringing out any nonconformities in order to avoid their presence in mass production.<\/strong><br\/>Tomographic inspection, thanks to both defectological and dimensional applications and the possibility of detecting both internal features (ducts, blind holes, internal circuits), enables accurate and reliable FAI characterization.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ed6b3e elementor-tablet-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"7ed6b3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#form\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">ASK FOR TOMOGRAPHIC TEST<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f3a99d e-flex e-con-boxed e-con e-parent\" data-id=\"4f3a99d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dbf2c56 e-con-full e-flex e-con e-child\" data-id=\"dbf2c56\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-41bd733 e-con-full e-flex e-con e-child\" data-id=\"41bd733\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbc3532 elementor-widget elementor-widget-heading\" data-id=\"dbc3532\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aerospace, biomedical and automotive: tomography applied to industries<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b213d0 elementor-widget elementor-widget-text-editor\" data-id=\"1b213d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Industrial tomography has crucial applications in the <strong>automotive, aerospace, and biomedical sectors<\/strong>, where accuracy and quality of components are critical.<\/p><p>In the <strong>automotive industry<\/strong>, it has the ability to perform tomographic scans on critical components such as engine blocks, valves, injectors, electronic components, etc., and <strong>allows internal defects such as cracks, porosity or inclusions to be detected more immediately than other techniques<\/strong>, providing an overall picture of the material\/component condition. This ensures that each part meets rigorous safety and performance standards. This type of nondestructive analysis is essential to prevent failures that could compromise vehicle safety.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1d07e64 e-con-full e-flex e-con e-child\" data-id=\"1d07e64\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9c3fc elementor-widget elementor-widget-text-editor\" data-id=\"1f9c3fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In <strong>aerospace<\/strong>, industrial tomography enables accurate inspection of critical parts such as turbines, engine blades, and composite components, where accuracy is critical to flight safety and operational reliability. The accuracy of tomographic analysis <strong>allows the detection of micro-defects that could evolve into serious problems during flight<\/strong>. In summary, industrial tomography is essential for maintaining high standards of safety, reliability, and performance in aircraft and aerospace equipment.  <\/p><p>In the <strong>biomedical industry<\/strong>, industrial tomography is used to ensure the quality and safety of medical devices, which often must meet extremely high standards. The ability to perform high-resolution scans allows <strong>implants and prostheses to be examined with micrometer precision<\/strong>, detecting defects that could compromise the functionality or biocompatibility of devices. In addition, the ability to analyze components made with additive technologies <strong>allows for continuous innovation and improvement of medical devices<\/strong>, ensuring that each product meets required specifications and is safe for clinical use.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-90eebe0 e-flex e-con-boxed e-con e-parent\" data-id=\"90eebe0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-57e09f1 e-con-full e-flex e-con e-child\" data-id=\"57e09f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2442402 elementor-widget elementor-widget-image\" data-id=\"2442402\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"812\" src=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/06\/benuzzi-1009x1024.jpg\" class=\"attachment-large size-large wp-image-14247\" alt=\"\" srcset=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/06\/benuzzi-1009x1024.jpg 1009w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/06\/benuzzi-296x300.jpg 296w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/06\/benuzzi-768x779.jpg 768w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/06\/benuzzi.jpg 1074w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-13f0176 e-con-full e-flex e-con e-child\" data-id=\"13f0176\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d539eab elementor-widget elementor-widget-heading\" data-id=\"d539eab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Schedule a technical discussion with our NDT Manager<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6494db3 elementor-widget elementor-widget-text-editor\" data-id=\"6494db3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>We will analyze your product specifications to define the most appropriate instrument setup and control plan to support your production.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b4d7d4 elementor-tablet-align-left elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"3b4d7d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.tec-eurolab.com\/en\/tomographic-inspection-and-industrial-3d-scanning-nondestructive-analysis\/\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">SPEAK WITH STEFANO BENUZZI<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f94bfc e-flex e-con-boxed e-con e-parent\" data-id=\"3f94bfc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-ba86aca e-con-full e-flex e-con e-child\" data-id=\"ba86aca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-4b11ee6 e-con-full e-flex e-con e-child\" data-id=\"4b11ee6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dfc2996 elementor-widget elementor-widget-image\" data-id=\"dfc2996\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"812\" src=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/case-study-tomografia-1009x1024.webp\" class=\"attachment-large size-large wp-image-8160\" alt=\"\" srcset=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/case-study-tomografia-1009x1024.webp 1009w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/case-study-tomografia-296x300.webp 296w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/case-study-tomografia-768x779.webp 768w, https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/02\/case-study-tomografia.webp 1074w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37c54f6 e-con-full e-flex e-con e-child\" data-id=\"37c54f6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bcb8926 elementor-widget elementor-widget-heading\" data-id=\"bcb8926\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Industrial computed tomography: comparing technologies in the inspection of high-density components.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03ada7d elementor-widget elementor-widget-text-editor\" data-id=\"03ada7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>How does the power of the source used affect the outcome of a CT scan?<\/p><p>In our Tomography Center, we compared the two most powerful systems (LINAC DIONDO D7 6MeV vs. NSI X7500 450 MeV) to scan a steel gear wheel and make both defectological and dimensional comparison of the outputs.<\/p><h3><strong>Want to read the full case study?<\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37b0740 elementor-tablet-align-center elementor-widget elementor-widget-button\" data-id=\"37b0740\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.tec-eurolab.com\/wp-content\/uploads\/2026\/06\/Tomografia-tecnologie-a-confronto.pdf\" target=\"_blank\" rel=\"nofollow\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">READ MORE<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e70a09 e-flex e-con-boxed e-con e-parent\" data-id=\"9e70a09\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-f0d68d3 e-con-full e-flex e-con e-child\" data-id=\"f0d68d3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d9a9a03 e-con-full e-flex e-con e-child\" data-id=\"d9a9a03\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bb8da27 elementor-widget elementor-widget-heading\" data-id=\"bb8da27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Technical characteristics of materials tomography<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3198c47 elementor-widget elementor-widget-text-editor\" data-id=\"3198c47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In order to perform industrial tomography, it is first necessary to know the purpose of the tomographic scan and the component to be analyzed.<br\/>In fact, if a component is large and composed of high-density alloys, probably only the LINAC will be able to obtain acceptable results. If, on the other hand, the purpose is to find small discontinuities, then it will be necessary to use the tomograph that allows the highest resolution to be achieved. <\/p><p>In general, based on these data, <strong>each scan requires making several considerations to set the many technical parameters needed to optimize the quality of the tomographic scan.<\/strong> These considerations, for example, are:<br\/>&#8211; <strong>Size and weight of the component:<\/strong> based on this data, the most suitable tomograph for the component will be chosen. At TEC Eurolab, we are able to scan components weighing up to 200kg and with a scannable volume equal to a cylinder with a diameter of 1.5m and a height of 4m.<br\/>&#8211; <strong>Material of the component:<\/strong> the most suitable tomograph will also be chosen based on this parameter. With the LINAC 6.0 MeV tomograph, we can perform tomographic scans on super alloy components.<br\/>&#8211; <strong>Fixing the component:<\/strong> the component during the scan must remain stationary, at this stage I have to ask myself: how do I fix it in such a way that it does not move during the movement of the various components of the tomographic system?<br\/>&#8211; <strong>Purpose of the scan:<\/strong> dimensional and\/or defectological? What do I want to achieve?   <\/p><p>From these considerations derive the subsequent &#8220;settings&#8221; of the system parameters, including<br\/>&#8211; <strong>Voltage (kV):<\/strong> determines the penetrative capacity of the photon beam through the object being analyzed, the greater the size and\/or density of the material, the greater this value will have to be<br\/>&#8211; <strong>Current (uA)<\/strong>: signal intensity that reaches the detector<br\/>&#8211;<strong> Resolution (\u00b5m)<\/strong>: is the parameter on which the smallest detectable feature on a tomography image depends<br\/>&#8211;<strong> No. of projections<\/strong>: images that will be collected by the system to then reconstruct the tomographic volume<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-da2f10f e-con-full e-flex e-con e-child\" data-id=\"da2f10f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dceb18d e-con-full e-flex e-con e-child\" data-id=\"dceb18d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-383ef1d elementor-widget elementor-widget-heading\" data-id=\"383ef1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">The stages of tomographic analysis\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a794866 elementor-widget elementor-widget-text-editor\" data-id=\"a794866\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\tTo carry out a tomographic analysis, the analysis steps are as follows:\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34735b1 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"34735b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-arrow-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M190.5 66.9l22.2-22.2c9.4-9.4 24.6-9.4 33.9 0L441 239c9.4 9.4 9.4 24.6 0 33.9L246.6 467.3c-9.4 9.4-24.6 9.4-33.9 0l-22.2-22.2c-9.5-9.5-9.3-25 .4-34.3L311.4 296H24c-13.3 0-24-10.7-24-24v-32c0-13.3 10.7-24 24-24h287.4L190.9 101.2c-9.8-9.3-10-24.8-.4-34.3z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Insertion of the component inside the industrial tomograph<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-arrow-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M190.5 66.9l22.2-22.2c9.4-9.4 24.6-9.4 33.9 0L441 239c9.4 9.4 9.4 24.6 0 33.9L246.6 467.3c-9.4 9.4-24.6 9.4-33.9 0l-22.2-22.2c-9.5-9.5-9.3-25 .4-34.3L311.4 296H24c-13.3 0-24-10.7-24-24v-32c0-13.3 10.7-24 24-24h287.4L190.9 101.2c-9.8-9.3-10-24.8-.4-34.3z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">setting of scanning parameters<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-arrow-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M190.5 66.9l22.2-22.2c9.4-9.4 24.6-9.4 33.9 0L441 239c9.4 9.4 9.4 24.6 0 33.9L246.6 467.3c-9.4 9.4-24.6 9.4-33.9 0l-22.2-22.2c-9.5-9.5-9.3-25 .4-34.3L311.4 296H24c-13.3 0-24-10.7-24-24v-32c0-13.3 10.7-24 24-24h287.4L190.9 101.2c-9.8-9.3-10-24.8-.4-34.3z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">scan initiation and data collection<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-arrow-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M190.5 66.9l22.2-22.2c9.4-9.4 24.6-9.4 33.9 0L441 239c9.4 9.4 9.4 24.6 0 33.9L246.6 467.3c-9.4 9.4-24.6 9.4-33.9 0l-22.2-22.2c-9.5-9.5-9.3-25 .4-34.3L311.4 296H24c-13.3 0-24-10.7-24-24v-32c0-13.3 10.7-24 24-24h287.4L190.9 101.2c-9.8-9.3-10-24.8-.4-34.3z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Reconstruction of the virtual volume of the component by the workstation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-arrow-right\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M190.5 66.9l22.2-22.2c9.4-9.4 24.6-9.4 33.9 0L441 239c9.4 9.4 9.4 24.6 0 33.9L246.6 467.3c-9.4 9.4-24.6 9.4-33.9 0l-22.2-22.2c-9.5-9.5-9.3-25 .4-34.3L311.4 296H24c-13.3 0-24-10.7-24-24v-32c0-13.3 10.7-24 24-24h287.4L190.9 101.2c-9.8-9.3-10-24.8-.4-34.3z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">analysis of the scan obtained with dedicated software<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f9aa570 e-con-full e-flex e-con e-child\" data-id=\"f9aa570\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d915eca elementor-widget elementor-widget-heading\" data-id=\"d915eca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tools of tomography<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d10c303 elementor-widget elementor-widget-text-editor\" data-id=\"d10c303\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>TEC Eurolab<\/strong> was a <strong>forerunner of this new analysis technology<\/strong> and the first tomographic laboratory in Italy to install this instrumentation in 2013.<br\/>Today we have three tomographic systems with different characteristics and potentials, from 240 Kv up to 6 MeV.  <\/p><p>Learn in detail about the <a href=\"https:\/\/www.tec-eurolab.com\/en\/tomographic-systems\/\">equipment in our tomography center<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28dff86 elementor-widget elementor-widget-menu-anchor\" data-id=\"28dff86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"form\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8a3eaec e-flex e-con-boxed e-con e-parent\" data-id=\"8a3eaec\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6867cfc e-con-full e-flex e-con e-child\" data-id=\"6867cfc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6a5dad1 e-con-full e-flex e-con e-child\" data-id=\"6a5dad1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-44acec8 elementor-widget elementor-widget-heading\" data-id=\"44acec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Do you want to discover the potential of industrial tomography applied to your product?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3670843 elementor-widget elementor-widget-text-editor\" data-id=\"3670843\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\tRequest information  \n\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-df5caa1 e-con-full e-flex e-con e-child\" data-id=\"df5caa1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8fc78a9 elementor-button-align-stretch elementor-widget elementor-widget-global elementor-global-9033 elementor-global-8569 elementor-widget-form\" data-id=\"8fc78a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;button_width&quot;:&quot;100&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"Testing module\" aria-label=\"Testing module\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"13586\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"8fc78a9\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-above\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-50 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tCompany\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-lg  elementor-field-textual\" placeholder=\"Company\" required=\"required\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-50 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tEmail\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-lg  elementor-field-textual\" placeholder=\"Email\" required=\"required\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-nome elementor-col-50\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-nome\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tName\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[nome]\" id=\"form-field-nome\" class=\"elementor-field elementor-size-lg  elementor-field-textual\" placeholder=\"Name\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tSubject of the request\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-lg\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Subject of the request\" required=\"required\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-upload elementor-field-group elementor-column elementor-field-group-upload_1 elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-upload_1\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tUPLOAD ATTACHMENTS\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t<input type=\"file\" name=\"form_fields[upload_1]\" id=\"form-field-upload_1\" class=\"elementor-field elementor-size-lg  elementor-upload-field\" data-maxsize=\"15\" data-maxsize-message=\"This file exceeds the maximum allowed size.\">\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-html elementor-field-group elementor-column elementor-field-group-field_e3b5c45 elementor-col-100\">\n\t\t\t\t\t(max size 10 Mb - allowed formats pdf, doc)\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-acceptance elementor-field-group elementor-column elementor-field-group-privacy elementor-col-100 elementor-field-required elementor-mark-required\">\n\t\t\t\t\t\t\t<div class=\"elementor-field-subgroup\">\n\t\t\t<span class=\"elementor-field-option\">\n\t\t\t\t<input type=\"checkbox\" name=\"form_fields[privacy]\" id=\"form-field-privacy\" class=\"elementor-field elementor-size-lg  elementor-acceptance-field\" required=\"required\">\n\t\t\t\t<label for=\"form-field-privacy\">I authorize the processing of personal data to follow up my request as stated in the <a href=\"https:\/\/www.privacylab.it\/informativa.php?04432308039\" target=\"_blank\" rel=\"noopener\">privacy policy<\/a><span style=\"color:#ff0000;\"> *<\/span><\/label>\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-acceptance elementor-field-group elementor-column elementor-field-group-privacy_2 elementor-col-100\">\n\t\t\t\t\t\t\t<div class=\"elementor-field-subgroup\">\n\t\t\t<span class=\"elementor-field-option\">\n\t\t\t\t<input type=\"checkbox\" name=\"form_fields[privacy_2]\" id=\"form-field-privacy_2\" class=\"elementor-field elementor-size-lg  elementor-acceptance-field\">\n\t\t\t\t<label for=\"form-field-privacy_2\">I provide consent to the processing of personal data for marketing purposes as outlined in the <a href=\"https:\/\/www.privacylab.it\/informativa.php?04432449333\" target=\"_blank\" rel=\"noopener\">privacy policy<\/a> and declare that I am at least 14 years of age.<\/label>\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-100 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-lg\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Send<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Home Industrial tomography is non-destructive testing, an advanced technology that allows detailed three-dimensional images of an object to be obtained using X-rays . This technique is critical for the analysis and verification of components and their material (material tomography), allowing detection of defects, inclusions, and porosity that would otherwise be invisible. Industrial tomography, or industrial [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-13586","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages\/13586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/comments?post=13586"}],"version-history":[{"count":4,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages\/13586\/revisions"}],"predecessor-version":[{"id":14395,"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/pages\/13586\/revisions\/14395"}],"wp:attachment":[{"href":"https:\/\/www.tec-eurolab.com\/en\/wp-json\/wp\/v2\/media?parent=13586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}